Tuning Fork Tests (Rinne, Weber, ABC) & Conductive vs Sensorineural Hearing Loss
High-Yield Clinical Pearls & Exam Keys
Standard Clinical Fork = 512 Hz (Gardiner Brown): strikes ideal balance — higher forks decay too quickly, lower forks (128/256 Hz) evoke tactile bone VIBRATION rather than pure auditory tone. Struck gently at the junction of UPPER 1/3 and LOWER 2/3 of the prong!
Rinne Test (AC vs BC in same ear): Normal / SNHL -> AC > BC ('Rinne POSITIVE'!). Conductive Hearing Loss (>15-20 dB air-bone gap) -> BC > AC ('Rinne NEGATIVE'!). Watch out for FALSE NEGATIVE Rinne in profound unilateral SNHL (sound crosses skull to opposite normal cochlea -> mask contralateral ear with Barany noise box!).
Weber Test (512 Hz on forehead/glabella/upper incisors): Normal -> midline/central; Unilateral CHL -> LATERALIZES TO DISEASED (WORSE) EAR (ambient masking lost + Bing occlusion amplification); Unilateral SNHL -> LATERALIZES TO HEALTHY (BETTER) EAR!
Schwabach & Absolute Bone Conduction (ABC): ABC occludes both patient & examiner external auditory meatuses to remove ambient noise masking -> SNHL shows REDUCED ABC compared to examiner (Normal/CHL = ABC same as examiner!). Rinne negative at 256 Hz -> >=15-20 dB loss; 512 Hz -> >=25-30 dB; 1024 Hz -> >=40-45 dB!
Ask Dr. Medarro about ENT (Otorhinolaryngology)
Instant NMC-grounded answers with standard textbook citations
Special Tuning Fork Tests (Gelle, Bing, False Negative Rinne)
GELLE'S TEST: Compress air in EAC via Siegle speculum -> Normal ear shows DECREASED bone conduction -> OTOSCLEROSIS (stapes footplate fixed) shows NO CHANGE ('Gelle Negative' — absent decrement!)
BING TEST: Occlude tragus while fork on mastoid -> Normal/SNHL hears LOUDER ('Bing Positive') -> Conductive HL / Otosclerosis shows NO loudness change ('Bing Negative')
FALSE NEGATIVE RINNE (Unilateral Dead Ear): Apparent BC > AC because contralateral healthy cochlea picks up mastoid vibration via transcranial attenuation (0-5 dB), exposed when Barany noise box masks normal ear!
Conductive vs Sensorineural vs Mixed Hearing Loss — Clinical & Audiometric Matrix
| Test / Parameter | Conductive Hearing Loss (CHL) | Sensorineural Hearing Loss (SNHL) |
|---|---|---|
| Rinne Test (512 Hz) | NEGATIVE (BC > AC when AB gap > 20 dB) | POSITIVE (AC > BC, both reduced in proportion) |
| Weber Test | Lateralizes to WORSE / DISEASED ear | Lateralizes to BETTER / HEALTHY ear |
| Absolute Bone Conduction (ABC) | Normal (Equal to examiner's bone threshold) | REDUCED (Patient stops hearing earlier than examiner) |
| Pure Tone Audiometry (PTA) | Normal BC (<=20 dB); raised AC -> AIR-BONE GAP >= 15 dB | Both AC and BC raised together; NO Air-Bone gap |
| Speech Discrimination / Recruitment | Good speech discrimination; NO recruitment or Paracusis | Poor speech discrimination (retrocochlear worst); Recruitment positive in cochlear lesions (Meniere's) |
Interactive Clinical Vignette Practice
Live Rule-Out EngineA 38-year-old man complains of right-sided deafness after a viral illness. Rinne test with 512 Hz is NEGATIVE in the right ear and POSITIVE in the left ear. Weber test lateralizes strongly to the LEFT ear. What is the single next step to confirm the true pathology?